Assessment of irrigation water quality on surface water sources
| dc.contributor.author | Matanda, Tatenda Patience | |
| dc.date.accessioned | 2026-10-07T10:17:19Z | |
| dc.date.issued | 2026-06 | |
| dc.description.abstract | The quality of irrigation water plays a vital role in determining the health status of soil and crop productivity. This study evaluates the quality of water drawn from SOS dam at Bindura University of Science education (BUSE) farm based on the physicochemical and biological parameters. Four sampling times were conducted from April to May 2026. Ten sampling sites (S1-S10) were set at different location in the dam and samples were collected at weekly basis. Parameters tested include temperature, pH, electrical conductivity (EC) and total coliform bacteria. Physicochemical parameters were analyzed using portable multi-parameter meter while biological parameter were analyzed using the pour plate technique on MacConkey agar. The data was analyzed by Analysis of Variance (ANOVA) using GenStat software and treatment means were separated using Least Significant Difference (LSD) test at 5% significant level. The results indicated that the temperature varied between 23.53ﹾⅭ and 26.10ﹾⅭ with relative constancy through time of the experiment. There was a significant difference (p≤ 0.05) in pH and EC among the sampling point, however, significant difference in temperature was noticed only during the late stage of sampling periods. The mean value of pH varied from 6.50 to 9.23 while mean value of EC was 213.3 to 316.3µS/cm indicating presence of low to moderate salinity danger. No significant difference (p>0.05) was seen in total coliform count among the sampling points. This implied uniformity in microbial contamination in the dam. In general, the physicochemical parameters analyzed were within acceptable range for irrigation water. However, some of the sampling points had slightly higher pH values. The conclusion reached by the study was that the SOS Dam water is suitable for irrigation and gardening purposes. Nevertheless, regular testing of the quality of the water should be done for any change that may occur due to the above stated reasons. | |
| dc.identifier.uri | https://ir.buse.ac.zw/handle/123456789/698 | |
| dc.language.iso | en | |
| dc.publisher | BUSE | |
| dc.subject | Irrigation water quality | |
| dc.subject | Surface water | |
| dc.subject | Electrical conductivity | |
| dc.title | Assessment of irrigation water quality on surface water sources | |
| dc.type | Thesis |